This page lists the 7 eligible heat pump systems shared publicly on heatpumpmonitor.org with this installer recorded, and their measured performance over the last 365 days. Recorded on heatpumpmonitor.org as "Greenhome Heating Ltd".
Last checked 14 November 2026. Installer website as recorded: greenhomeheating.co.uk (not linked: the site returned HTTP 202 rather than a normal page to our automated link checks on 16 and 17 November 2026, so we could not verify it)
| System | Location (as published) | Heat pump | Rated output | 12-month SCOP | Days of data | Flow temp while running | Design flow temp | MID metering / boundary |
|---|---|---|---|---|---|---|---|---|
| System 282 | Longframlington, Northumberland | Vaillant Arotherm+ | 7.0 kW | 4.25 | 357 | 31.5 °C | 40 °C | Yes / H4 |
| System 371 | Prudhoe, Northumberland | Vaillant Arotherm+ | 5.0 kW | 3.47 | 363 | 28.1 °C | 40 °C | Yes / H4 |
| System 372 | Morpeth, Northumberland | Vaillant Arotherm+ | 7.0 kW | 3.92 | 364 | 31.3 °C | 40 °C | Yes / H4 |
| System 527 | St Asaph, Denbighshire | Vaillant Arotherm+ | 7.0 kW | 4.40 | 364 | 33.9 °C | 40 °C | Yes / H4 |
| System 545 | Newcastle | Vaillant Arotherm+ | 5.0 kW | 4.51 | 363 | 31.1 °C | 40 °C | Yes / H4 |
| System 608 | Wylam | Vaillant Arotherm+ | 12.0 kW | 4.52 | 357 | 31.3 °C | 45 °C | Yes / H4 |
| System 624 | Whitley Bay, North Tyneside | Vaillant Arotherm+ | 5.0 kW | 4.19 | 362 | 32.8 °C | 45 °C | Yes / H4 |
Definitions. "12-month SCOP" is heatpumpmonitor.org's combined COP (space heating plus hot water) over the last 365 days, from /system/stats/last365 (combined_cop). "Flow temp while running" is the mean flow temperature while the heat pump was running (running_flowT_mean). "Design flow temp" is the value entered for the system. Only UK systems (by published coordinates, with the location text confirming Northern Ireland) with at least 300 days of data in the last 365 days, no heatpumpmonitor.org data flag, and no duplicate key stats are included. Medians and ranges are across the systems listed.
Check current MCS certification on the MCS Find an Installer page. We don't reproduce MCS data.
If you represent Greenhome Heating Limited, or you own a system listed here, and think something is wrong, out of date or missing context, contact us at hello@provenheatpumps.co.uk. We'll review it and, where appropriate, correct the page or publish your response alongside it. System owners can ask for their system to be removed from our pages.