Proven Heat Pumps: all pages

Methodology and data sources

This page explains how the pages on this site are built by build.py. It describes the current build, last checked 14 November 2026.

Data sources

Performance data from heatpumpmonitor.org (OpenEnergyMonitor), licensed CC BY 4.0.

Performance figures come from heatpumpmonitor.org public endpoints, which its About page licences under CC BY 4.0:

The build uses a saved snapshot of those endpoints (currently heatpumpmonitor-public-systems-2026-11-14.json and heatpumpmonitor-stats-last365-2026-11-14.json). Figures are selected and summarised from that snapshot; the underlying values are not changed.

Company records come from the public Companies House website (find-and-update.company-information.service.gov.uk). A Companies House section is shown on an installer page only when the company number in the build configuration is found on that installer's own website at build time. Installer pages use a registered company name or a business trading name, not a person's name. In this build, a company record is shown for 16 of 17 installers that have a company number in the configuration.

Measured figures, not manufacturer claims

The figures on these pages are measured results from systems whose owners chose to share data publicly on heatpumpmonitor.org. They are not manufacturer claims, and they are not every installation. "12-month SCOP" is heatpumpmonitor.org's combined COP (space heating plus hot water) over the last 365 days (combined_cop from /system/stats/last365). "Flow temp while running" is the mean flow temperature while the heat pump was running (running_flowT_mean).

Medians and minimum sample sizes

The median 12-month SCOP on a page is the median of combined_cop for the systems listed on that page. The median flow temperature while running is the median of the recorded running_flowT_mean values; systems with no recorded value are left out of that median. Where a median design flow temperature is shown, it is the median of the design flow temperatures entered for the listed systems that have one.

Medians use Python's statistics.median: the middle value when there is an odd number of figures, or the mean of the two middle values when there is an even number. Ranges shown alongside a median are the minimum and maximum of the same list.

A page is only built when enough eligible systems match. The minimums in the build configuration are:

This build has 19 installer pages, 6 model pages and 4 area pages.

UK filter, other exclusions, and duplicate-system detection

This build includes 486 eligible systems out of 869 in the snapshot. 383 systems are excluded.

UK filter. A system is treated as UK only if it has published coordinates inside a Great Britain bounding box (latitude 49.85 to 60.95, longitude -8.7 to 1.9). Coordinates that fall on the island of Ireland are included only when the published location text names Northern Ireland or a listed Northern Ireland place. A system is excluded if it has no published coordinates, if its coordinates are outside that box, or if its location text names a non-UK place. If the location text names no other country but the coordinates are outside the UK, the location is treated as unverified and the system is excluded. There is no override list. In this build, 79 systems were classed as non-UK or unverified.

Other exclusions. Eligible systems also need last-365-day statistics with a combined COP, at least 300 days of data in the last 365 days, and no heatpumpmonitor.org data flag.

Duplicate-system detection. Systems whose last-365-day key statistics are identical are treated as a duplicate group: combined COP, electricity use, heat output, length of data, and mean flow temperature while running, rounded as in the build script. Every system in a duplicate group is excluded, because the build cannot tell which record is the original. In this build, 2 duplicate group(s) covering 4 systems were excluded.

Please read: what this page is and isn't

Right of reply and corrections

If you represent an installer or system owner, or you own a system listed here, and think something is wrong, out of date or missing context, contact us at hello@provenheatpumps.co.uk. We'll review it and, where appropriate, correct the page or publish your response alongside it. System owners can ask for their system to be removed from our pages.