Octopus Energy Services Limited: monitored heat pump systems

This page lists the 61 eligible heat pump systems shared publicly on heatpumpmonitor.org with this installer recorded, and their measured performance over the last 365 days. Recorded on heatpumpmonitor.org as "Octopus Energy Services".

Last checked 14 November 2026. Installer website as recorded: https://octopus.energy/

UK systems only. 1 system(s) recorded for this installer on heatpumpmonitor.org are outside the UK, or their published location could not be confirmed as UK, so they are not included on this page.

Median 12-month SCOP3.64range 2.67 to 4.61, 61 systems
Median flow temp while running35.3 °Crange 28.6 to 39.3 °C
Median design flow temp50 °Cas entered per system

Systems

SystemLocation (as published)Heat pumpRated output12-month SCOPDays of dataFlow temp while runningDesign flow tempMID metering / boundary
System 17Weston-super-MareDaikin Altherma 37.0 kW2.6735936.4 °C50 °CNo / H4
System 44Farnborough, HampshireDaikin Altherma 38.0 kW4.0136334.4 °C38 °CYes / H4
System 76Bristol UKDaikin Altherma 37.0 kW3.0132036.0 °C40 °CNo / H3
System 86CambridgeshireDaikin Altherma 311.0 kW3.8734434.8 °C42 °CNo / H2
System 111Reading UKDaikin Altherma 39.0 kW3.2532933.1 °C50 °CNo / H4
System 120HertfordshireDaikin Altherma 39.0 kW3.8436034.7 °C50 °CNo / H3
System 147Attleborough, NorfolkDaikin Altherma 34.0 kW3.3736437.3 °C45 °CNo / H4
System 162West OxfordshireDaikin Altherma 36.0 kW4.0036434.7 °C50 °CYes / H4
System 219Sudbury, SuffolkDaikin Altherma 34.0 kW3.2932436.2 °C45 °CNo / H4
System 224WokinghamDaikin Altherma 38.0 kW3.9836336.1 °C50 °CNo / H4
System 228BirminghamDaikin Altherma 34.0 kW3.0936434.6 °C45 °CYes / H3
System 259NorthamptonDaikin Altherma 39.0 kW2.9331631.8 °C50 °CNo / H3
System 279London, UKDaikin Altherma 311.0 kW4.2336334.9 °C50 °CNo / H4
System 293Stalmine, LancashireDaikin Altherma 39.0 kW3.8736438.2 °C50 °CNo / H3
System 295Marston MoretaineDaikin Altherma 39.0 kW3.0536333.9 °C50 °CYes / H2
System 310TelfordDaikin Altherma 34.0 kW3.3035537.9 °C50 °CNo / H3
System 338Buntingford, HertfordshireDaikin Altherma 34.0 kW3.6536339.3 °C50 °CNo / H4
System 351Marlborough, WiltshireDaikin Altherma 36.0 kW3.7436132.6 °C50 °CYes / H4
System 358BournemouthDaikin Altherma 38.0 kW3.8334836.4 °C50 °CNo / H3
System 364Lindfield, Mid SussexDaikin Altherma 38.0 kW4.1436035.9 °C50 °CYes / H4
System 421Horsham, West SussexDaikin Altherma 27.0 kW3.1136435.1 °C50 °CNo / H4
System 439Ruddington,NottinghamDaikin Altherma 39.0 kW3.6436336.7 °C50 °CYes / H4
System 450BathDaikin Altherma 38.0 kW3.8236333.7 °C50 °CNo / H4
System 454PooleDaikin Altherma6.0 kW3.3835434.1 °C50 °CNo / H3
System 460NorthwichDaikin Altherma 36.0 kW3.9735234.6 °C50 °CNo / H4
System 473Leyland, LancashireDaikin Altherma 36.0 kW4.1234528.6 °C50 °CNo / H3
System 522EssexDaikin Altherma 34.0 kW4.1531531.4 °C50 °CNo / H4
System 547Colchester, EssexOctopus Cosy6.0 kW3.2436338.0 °C50 °CNo / H4
System 549Leighton BuzzardDaikin Altherma 36.0 kW3.3736336.2 °C50 °CNo / H3
System 561MaidenheadDaikin Altherma 38.0 kW3.8732733.6 °C50 °CYes / H4
System 566EveshamDaikin Altherma 311.0 kW2.6736433.9 °C50 °CNo / H3
System 575Trowell, NottinghamDaikin Altherma 38.0 kW3.6135032.7 °C45 °CNo / H3
System 587Tonbridge and Malling, KentDaikin Altherma 36.0 kW3.4936437.3 °C50 °CYes / H4
System 599DerbyshireOctopus Cosy6.0 kW3.3232637.8 °C50 °CNo / H3
System 614NeathDaikin Altherma 38.0 kW4.2035734.9 °C50 °CNo / H4
System 615South Chingford, LondonDaikin Altherma 38.0 kW4.5836430.8 °C50 °CYes / H4
System 621Worcester, WorcestershireDaikin Altherma 311.0 kW2.8336438.1 °C50 °CYes / H4
System 627Suffolk, MildenhallDaikin Altherma 311.0 kW3.5735937.2 °C50 °CNo / H2
System 633NorfolkDaikin Altherma 38.0 kW3.4136438.1 °C50 °CNo / H4
System 636Claughton-On-Brock, LancashireDaikin Altherma 38.0 kW3.0933339.2 °C50 °CYes / H4
System 639Leighton Buzzard, BedfordshireDaikin Altherma 34.0 kW3.7236235.4 °C50 °CNo / H4
System 656NorthamptonshireDaikin Altherma 38.0 kW3.7536436.8 °C50 °CNo / H4
System 664Thurcroft, RotherhamOctopus Cosy6.0 kW3.1436238.9 °C50 °CYes / H4
System 685Pudsey, LeedsOctopus Cosy9.0 kW3.7036438.4 °C50 °CYes / H4
System 703Loughborough, LeicestershireOctopus Cosy6.0 kW4.2136338.1 °C50 °CNo / H3
System 704StaffordshireDaikin Altherma 38.0 kW4.6133236.0 °C50 °CNo / H2
System 707North HertfordshireDaikin Altherma 39.0 kW3.2736033.1 °C50 °CNo / H2
System 712Wigan, ManchesterDaikin Altherma 36.0 kW4.2236032.8 °C50 °CNo / H4
System 721DerbyshireDaikin Altherma 34.0 kW3.7635835.2 °C50 °CNo / H2
System 726OxfordshireDaikin Altherma 39.0 kW3.6933433.2 °C50 °CNo / H4
System 778Crowborough, East SussexDaikin Altherma 38.0 kW3.3236236.9 °C50 °CNo / H3
System 834Newcastle, Tyne and WearDaikin Altherma 36.0 kW3.7836338.7 °C45 °CNo / H4
System 857Grantham, LincolnshireDaikin Altherma 39.0 kW3.3934032.4 °C50 °CNo / H3
System 859Bolton, Greater ManchesterOctopus Cosy6.0 kW3.7836335.3 °C50 °CNo / H3
System 888Ellesmere Port, Cheshire West and ChesterDaikin Altherma 36.0 kW3.8536132.0 °C50 °CNo / H4
System 901CambridgeshireDaikin Altherma 38.0 kW3.4935236.9 °C50 °CNo / H4
System 903Church Crookham, HampshireDaikin Altherma 36.0 kW3.7435135.0 °C50 °CNo / H4
System 910Market DeepingDaikin Altherma 38.0 kW2.9235633.5 °C50 °CNo / H3
System 943Hove, East SussexDaikin Altherma 311.0 kW3.1632334.8 °C50 °CYes / H4
System 980Newcastle upon Tyne, Tyne and WearDaikin Altherma 39.0 kW3.3236437.3 °C50 °CYes / H2
System 1197Driffield, East Riding of YorkshireDaikin Altherma 34.3 kW3.0035936.7 °C50 °CYes / H4

Definitions. "12-month SCOP" is heatpumpmonitor.org's combined COP (space heating plus hot water) over the last 365 days, from /system/stats/last365 (combined_cop). "Flow temp while running" is the mean flow temperature while the heat pump was running (running_flowT_mean). "Design flow temp" is the value entered for the system. Only UK systems (by published coordinates, with the location text confirming Northern Ireland) with at least 300 days of data in the last 365 days, no heatpumpmonitor.org data flag, and no duplicate key stats are included. Medians and ranges are across the systems listed.

Certification

Check current MCS certification on the MCS Find an Installer page. We don't reproduce MCS data.

Badge for this page

If you represent Octopus Energy Services Limited, you can link to this page with the badge below. It says "Measured data from monitored installs" because the systems listed here are monitored and shared by their owners on heatpumpmonitor.org. It is not a rating, ranking or endorsement. A PNG version is at https://provenheatpumps.co.uk/badge/measured-data.png.

Measured data from monitored installs: Proven Heat Pumps

Embed code:

<a href="https://provenheatpumps.co.uk/octopus-energy-services.html"><img src="https://provenheatpumps.co.uk/badge/measured-data.svg" alt="Measured data from monitored installs: Proven Heat Pumps" width="319" height="60"></a>

Company record (Companies House)

Registered nameOCTOPUS ENERGY SERVICES LIMITED
Company number10434397
StatusActive (as shown on Companies House, 14 November 2026)
Incorporated18 October 2016
Nature of business (SIC)82990 - Other business support service activities not elsewhere classified
Why we're confident this is the same businessThe installer's own website states the number: https://octopus.energy/ ("Company number: 10434397").

Please read: what this page is and isn't

Right of reply and corrections

If you represent Octopus Energy Services Limited, or you own a system listed here, and think something is wrong, out of date or missing context, contact us at hello@provenheatpumps.co.uk. We'll review it and, where appropriate, correct the page or publish your response alongside it. System owners can ask for their system to be removed from our pages.