Proven Heat Pumps: all pages

Daikin Altherma 3 6 kW: measured performance in monitored homes

Systems recorded on heatpumpmonitor.org as manufacturer "Daikin", model "Altherma 3", rated output 6 kW: 12 eligible systems. Last checked 14 November 2026.

Median 12-month SCOP3.82range 3.37 to 4.22
Median flow temp while running34.5 °Crange 28.6 to 38.7 °C
Systems12minimum for a model page: 3

The spread between systems mostly reflects differences in homes, design and settings. It is not a measure of the product alone.

Refrigerant as recorded on heatpumpmonitor.org: R32 (12 of 12 systems). The manufacturer lists R32 for the Daikin Altherma 3 range (Daikin, Altherma 3 R product catalogue, Daikin UK, Altherma 3 Low Capacity Monobloc brochure).

Systems

SystemLocation (as published)Installer page12-month SCOPDays of dataFlow temp while runningDesign flow temp
System 162West OxfordshireOctopus Energy Services Limited4.0036434.7 °C50 °C
System 351Marlborough, WiltshireOctopus Energy Services Limited3.7436132.6 °C50 °C
System 460NorthwichOctopus Energy Services Limited3.9735234.6 °C50 °C
System 473Leyland, LancashireOctopus Energy Services Limited4.1234528.6 °C50 °C
System 549Leighton BuzzardOctopus Energy Services Limited3.3736336.2 °C50 °C
System 587Tonbridge and Malling, KentOctopus Energy Services Limited3.4936437.3 °C50 °C
System 712Wigan, ManchesterOctopus Energy Services Limited4.2236032.8 °C50 °C
System 745Cambridgeno page3.7736430.8 °C45 °C
System 810AberdeenshireBritish Gas New Heating Limited4.0436434.4 °C45 °C
System 834Newcastle, Tyne and WearOctopus Energy Services Limited3.7836338.7 °C45 °C
System 888Ellesmere Port, Cheshire West and ChesterOctopus Energy Services Limited3.8536132.0 °C50 °C
System 903Church Crookham, HampshireOctopus Energy Services Limited3.7435135.0 °C50 °C

Definitions. "12-month SCOP" is heatpumpmonitor.org's combined COP (space heating plus hot water) over the last 365 days, from /system/stats/last365 (combined_cop). "Flow temp while running" is the mean flow temperature while the heat pump was running (running_flowT_mean). "Design flow temp" is the value entered for the system. Only UK systems (by published coordinates, with the location text confirming Northern Ireland) with at least 300 days of data in the last 365 days, no heatpumpmonitor.org data flag, and no duplicate key stats are included. Medians and ranges are across the systems listed.

Looking for an installer? Check current MCS certification on the MCS Find an Installer page.

Please read: what this page is and isn't

Right of reply and corrections

If you represent Daikin or an installer of a listed system, or you own a system listed here, and think something is wrong, out of date or missing context, contact us at hello@provenheatpumps.co.uk. We'll review it and, where appropriate, correct the page or publish your response alongside it. System owners can ask for their system to be removed from our pages.