Hot water is the less efficient job for a heat pump in this sample. Across 296 systems that report hot water and space heating separately, the median hot water COP was 3.08 and the median space heating COP was 4.20. Hot water was a median 15% of the heat these systems delivered over the year (296 systems).
Hot water has to be heated to around 45 to 55 °C, and sometimes higher for a weekly legionella cycle, while space heating can run much cooler. Higher temperatures mean a lower COP. heatpumpmonitor.org splits the year's figures into hot water and space heating where the monitoring can tell them apart.
| Group | Systems | Median hot water COP | Hot water COP, 25th percentile | Hot water COP, 75th percentile | Median space heating COP | Median combined 12-month SCOP |
|---|---|---|---|---|---|---|
| All systems with both figures | 296 | 3.08 | 2.71 | 3.43 | 4.20 | 3.90 |
| Recorded hot water method | Systems | Median hot water COP | Median space heating COP |
|---|---|---|---|
| Cylinder with coil | 261 | 3.09 | 4.20 |
| Cylinder with plate heat exchanger | 28 | 3.07 | 4.17 |
| Phase change store | 4 | 2.31 | 3.90 |
Not shown because they have fewer than 3 systems: Thermal store (heat exchanger on output), Other.
Related: running costs, flow temperature and SCOP.
Sample size. 296 eligible UK systems feed this page. Data snapshot: heatpumpmonitor.org public system list and last-365-day statistics, downloaded 14 November 2026. Eligibility is the same as on every page of this site (UK only, at least 300 days of data in the last 365 days, no data flag, no duplicate records, positive COP and heat output); see the methodology. Hot water and space heating COPs are heatpumpmonitor.org's water_cop and space_cop for the last 365 days; only systems with both are used. COPs above 10 are treated as recording errors. The hot water share is water_heat_kwh ÷ combined_heat_kwh, left out where hot water heat would exceed total heat. The hot water method is the owner-recorded dhw_method. Groups with fewer than 3 systems are not shown. Where a table shows the 25th and 75th percentiles (Python statistics.quantiles, inclusive method), half of the group's systems fall between them. These are medians across a self-selected, monitoring-keen group of homes, so they describe this sample, not every UK home, and differences between groups are associations, not proof of cause.
Definitions. "12-month SCOP" is heatpumpmonitor.org's combined COP (space heating plus hot water) over the last 365 days, from /system/stats/last365 (combined_cop). "Flow temp while running" is the mean flow temperature while the heat pump was running (running_flowT_mean). "Design flow temp" is the value entered for the system. Only UK systems (by published coordinates, with the location text confirming Northern Ireland) with at least 300 days of data in the last 365 days, no heatpumpmonitor.org data flag, and no duplicate key stats are included. Medians and ranges are across the systems listed.
| System | Group | 12-month SCOP | Flow temp while running | Days of data |
|---|---|---|---|---|
| System 2 | Cylinder with coil | 4.04 | 33.8 °C | 364 |
| System 3 | Phase change store | 3.08 | 32.9 °C | 362 |
| System 7 | Cylinder with coil | 2.92 | 37.0 °C | 364 |
| System 9 | Cylinder with plate heat exchanger | 3.75 | 33.5 °C | 364 |
| System 11 | Cylinder with coil | 2.80 | 35.3 °C | 349 |
| System 14 | Cylinder with coil | 3.79 | 35.5 °C | 359 |
| System 17 | Cylinder with coil | 2.67 | 36.4 °C | 359 |
| System 32 | Cylinder with coil | 3.46 | 37.0 °C | 356 |
| System 37 | Cylinder with coil | 4.05 | 31.7 °C | 301 |
| System 44 | Cylinder with coil | 4.01 | 34.4 °C | 363 |
| System 56 | Cylinder with coil | 3.34 | 39.5 °C | 361 |
| System 59 | Phase change store | 4.27 | 35.0 °C | 362 |
| System 61 | Cylinder with coil | 3.42 | 33.8 °C | 360 |
| System 66 | Cylinder with coil | 4.75 | 34.6 °C | 343 |
| System 68 | Cylinder with coil | 4.86 | 29.3 °C | 363 |
| System 71 | Cylinder with coil | 3.89 | 30.8 °C | 363 |
| System 75 | Cylinder with coil | 4.41 | 33.9 °C | 363 |
| System 76 | Cylinder with coil | 3.01 | 36.0 °C | 320 |
| System 86 | Cylinder with plate heat exchanger | 3.87 | 34.8 °C | 344 |
| System 111 | Cylinder with coil | 3.25 | 33.1 °C | 329 |
| System 114 | Cylinder with coil | 4.21 | 35.8 °C | 344 |
| System 115 | Cylinder with coil | 4.23 | 32.0 °C | 364 |
| System 116 | Cylinder with coil | 4.59 | 32.4 °C | 352 |
| System 120 | Cylinder with coil | 3.84 | 34.7 °C | 360 |
| System 126 | Cylinder with coil | 4.12 | 31.0 °C | 361 |
| System 139 | Cylinder with coil | 4.69 | 30.9 °C | 358 |
| System 140 | Cylinder with coil | 4.31 | 33.3 °C | 364 |
| System 147 | Cylinder with coil | 3.37 | 37.3 °C | 364 |
| System 159 | Cylinder with coil | 3.84 | 31.0 °C | 345 |
| System 162 | Cylinder with coil | 4.00 | 34.7 °C | 364 |
| System 163 | Cylinder with plate heat exchanger | 3.07 | 22.3 °C | 364 |
| System 173 | Cylinder with coil | 3.28 | 36.6 °C | 359 |
| System 204 | Cylinder with coil | 5.97 | 31.7 °C | 358 |
| System 210 | Cylinder with coil | 3.90 | 35.4 °C | 364 |
| System 211 | Cylinder with coil | 3.22 | 37.4 °C | 363 |
| System 219 | Cylinder with coil | 3.29 | 36.2 °C | 324 |
| System 224 | Cylinder with coil | 3.98 | 36.1 °C | 363 |
| System 240 | Phase change store | 3.16 | 39.1 °C | 361 |
| System 250 | Phase change store | 3.43 | 37.1 °C | 361 |
| System 254 | Cylinder with coil | 4.15 | 31.7 °C | 364 |
| System 259 | Cylinder with plate heat exchanger | 2.93 | 31.8 °C | 316 |
| System 260 | Cylinder with coil | 4.28 | 34.7 °C | 362 |
| System 262 | Cylinder with coil | 4.32 | 29.8 °C | 350 |
| System 266 | Cylinder with coil | 3.13 | 40.7 °C | 364 |
| System 272 | Cylinder with coil | 3.63 | 33.5 °C | 363 |
| System 279 | Cylinder with coil | 4.23 | 34.9 °C | 363 |
| System 280 | Cylinder with coil | 4.61 | 32.2 °C | 364 |
| System 284 | Cylinder with coil | 4.38 | 33.7 °C | 363 |
| System 287 | Cylinder with coil | 3.53 | 36.6 °C | 332 |
| System 288 | Cylinder with coil | 3.85 | 37.4 °C | 364 |
| System 293 | Cylinder with coil | 3.87 | 38.2 °C | 364 |
| System 295 | Cylinder with coil | 3.05 | 33.9 °C | 363 |
| System 296 | Cylinder with coil | 4.25 | 33.2 °C | 364 |
| System 297 | Cylinder with coil | 4.28 | 32.2 °C | 363 |
| System 299 | Cylinder with coil | 3.72 | 36.2 °C | 364 |
| System 301 | Cylinder with coil | 3.38 | 37.5 °C | 362 |
| System 302 | Cylinder with plate heat exchanger | 3.58 | 34.1 °C | 361 |
| System 310 | Cylinder with coil | 3.30 | 37.9 °C | 355 |
| System 314 | Cylinder with coil | 4.17 | 30.4 °C | 356 |
| System 315 | Cylinder with coil | 3.43 | 38.7 °C | 364 |
| System 326 | Cylinder with plate heat exchanger | 4.49 | 32.8 °C | 363 |
| System 330 | Cylinder with coil | 3.51 | 40.3 °C | 364 |
| System 333 | Thermal store (heat exchanger on output) | 2.92 | 44.6 °C | 364 |
| System 335 | Cylinder with coil | 4.25 | 35.4 °C | 364 |
| System 337 | Other | 4.28 | 27.7 °C | 358 |
| System 338 | Cylinder with coil | 3.65 | 39.3 °C | 363 |
| System 341 | Cylinder with coil | 3.45 | 32.4 °C | 364 |
| System 342 | Cylinder with coil | 4.23 | 34.2 °C | 364 |
| System 345 | Cylinder with coil | 4.17 | 31.7 °C | 360 |
| System 346 | Cylinder with coil | 4.08 | 30.0 °C | 364 |
| System 347 | Cylinder with coil | 3.91 | 34.8 °C | 364 |
| System 356 | Cylinder with coil | 3.77 | 34.1 °C | 347 |
| System 358 | Cylinder with coil | 3.83 | 36.4 °C | 348 |
| System 362 | Cylinder with coil | 3.35 | 39.5 °C | 364 |
| System 363 | Cylinder with coil | 4.13 | 30.7 °C | 364 |
| System 364 | Cylinder with coil | 4.14 | 35.9 °C | 360 |
| System 371 | Cylinder with plate heat exchanger | 3.47 | 28.1 °C | 363 |
| System 373 | Cylinder with coil | 4.73 | 32.4 °C | 363 |
| System 376 | Cylinder with plate heat exchanger | 3.14 | 32.6 °C | 352 |
| System 378 | Cylinder with coil | 4.77 | 31.6 °C | 324 |
| System 380 | Cylinder with coil | 4.12 | 32.1 °C | 364 |
| System 381 | Cylinder with coil | 4.29 | 32.6 °C | 324 |
| System 382 | Cylinder with coil | 4.37 | 31.5 °C | 363 |
| System 384 | Cylinder with coil | 3.74 | 33.3 °C | 360 |
| System 386 | Cylinder with plate heat exchanger | 4.15 | 36.7 °C | 363 |
| System 405 | Cylinder with coil | 3.52 | 37.8 °C | 337 |
| System 408 | Cylinder with coil | 3.92 | 26.7 °C | 363 |
| System 409 | Cylinder with plate heat exchanger | 3.29 | 40.9 °C | 359 |
| System 416 | Cylinder with coil | 3.91 | 34.8 °C | 309 |
| System 417 | Cylinder with coil | 3.40 | 34.8 °C | 364 |
| System 421 | Cylinder with coil | 3.11 | 35.1 °C | 364 |
| System 424 | Cylinder with plate heat exchanger | 4.87 | 30.4 °C | 363 |
| System 428 | Cylinder with plate heat exchanger | 4.42 | 30.7 °C | 362 |
| System 429 | Cylinder with coil | 3.11 | 33.9 °C | 364 |
| System 431 | Cylinder with plate heat exchanger | 4.52 | 31.3 °C | 340 |
| System 439 | Cylinder with coil | 3.64 | 36.7 °C | 363 |
| System 450 | Cylinder with coil | 3.82 | 33.7 °C | 363 |
| System 451 | Cylinder with coil | 3.25 | 38.0 °C | 307 |
| System 454 | Cylinder with coil | 3.38 | 34.1 °C | 354 |
| System 456 | Cylinder with plate heat exchanger | 4.01 | 34.5 °C | 364 |
| System 458 | Cylinder with coil | 4.60 | 32.2 °C | 363 |
| System 460 | Cylinder with coil | 3.97 | 34.6 °C | 352 |
| System 470 | Cylinder with coil | 4.28 | 31.8 °C | 360 |
| System 473 | Cylinder with plate heat exchanger | 4.12 | 28.6 °C | 345 |
| System 477 | Cylinder with coil | 4.98 | 29.9 °C | 364 |
| System 478 | Cylinder with coil | 2.94 | 34.8 °C | 364 |
| System 479 | Cylinder with coil | 5.23 | 25.5 °C | 364 |
| System 480 | Cylinder with coil | 3.28 | 40.4 °C | 321 |
| System 506 | Cylinder with coil | 4.43 | 29.0 °C | 331 |
| System 512 | Cylinder with coil | 4.50 | 30.5 °C | 364 |
| System 517 | Cylinder with coil | 3.98 | 34.3 °C | 329 |
| System 518 | Cylinder with coil | 3.19 | 37.4 °C | 364 |
| System 519 | Cylinder with plate heat exchanger | 4.02 | 33.7 °C | 364 |
| System 521 | Cylinder with coil | 3.35 | 28.4 °C | 343 |
| System 522 | Cylinder with coil | 4.15 | 31.4 °C | 315 |
| System 525 | Cylinder with coil | 3.61 | 31.4 °C | 360 |
| System 527 | Cylinder with coil | 4.40 | 33.9 °C | 364 |
| System 534 | Cylinder with coil | 3.20 | 39.7 °C | 345 |
| System 539 | Cylinder with coil | 3.82 | 35.3 °C | 363 |
| System 541 | Cylinder with coil | 2.74 | 37.3 °C | 364 |
| System 542 | Cylinder with coil | 4.84 | 26.9 °C | 326 |
| System 545 | Cylinder with coil | 4.51 | 31.1 °C | 363 |
| System 547 | Cylinder with coil | 3.24 | 38.0 °C | 363 |
| System 549 | Cylinder with coil | 3.37 | 36.2 °C | 363 |
| System 552 | Cylinder with plate heat exchanger | 3.92 | 32.1 °C | 364 |
| System 555 | Cylinder with coil | 2.75 | 45.7 °C | 309 |
| System 557 | Cylinder with coil | 3.98 | 34.3 °C | 364 |
| System 559 | Cylinder with plate heat exchanger | 3.55 | 36.0 °C | 345 |
| System 560 | Cylinder with coil | 3.29 | 40.3 °C | 362 |
| System 561 | Cylinder with coil | 3.87 | 33.6 °C | 327 |
| System 564 | Cylinder with coil | 4.50 | 31.0 °C | 361 |
| System 565 | Cylinder with coil | 4.50 | 33.0 °C | 364 |
| System 566 | Cylinder with coil | 2.67 | 33.9 °C | 364 |
| System 568 | Cylinder with coil | 5.09 | 28.1 °C | 346 |
| System 569 | Cylinder with coil | 4.19 | 33.4 °C | 364 |
| System 574 | Cylinder with coil | 4.61 | 28.4 °C | 363 |
| System 575 | Cylinder with coil | 3.61 | 32.7 °C | 350 |
| System 576 | Cylinder with plate heat exchanger | 4.12 | 35.7 °C | 363 |
| System 579 | Cylinder with coil | 3.25 | 37.9 °C | 355 |
| System 581 | Cylinder with coil | 3.29 | 42.2 °C | 364 |
| System 585 | Cylinder with coil | 3.84 | 35.7 °C | 361 |
| System 587 | Cylinder with plate heat exchanger | 3.49 | 37.3 °C | 364 |
| System 595 | Cylinder with coil | 3.78 | 37.1 °C | 363 |
| System 597 | Cylinder with coil | 4.37 | 32.9 °C | 347 |
| System 604 | Cylinder with coil | 4.38 | 31.0 °C | 360 |
| System 605 | Cylinder with coil | 3.94 | 34.7 °C | 362 |
| System 608 | Cylinder with coil | 4.52 | 31.3 °C | 357 |
| System 611 | Cylinder with coil | 4.28 | 29.6 °C | 364 |
| System 612 | Cylinder with coil | 4.24 | 33.3 °C | 341 |
| System 614 | Cylinder with coil | 4.20 | 34.9 °C | 357 |
| System 615 | Cylinder with coil | 4.58 | 30.8 °C | 364 |
| System 621 | Cylinder with coil | 2.83 | 38.1 °C | 364 |
| System 624 | Cylinder with coil | 4.19 | 32.8 °C | 362 |
| System 625 | Cylinder with coil | 3.37 | 37.0 °C | 363 |
| System 626 | Cylinder with coil | 2.55 | 43.7 °C | 320 |
| System 627 | Cylinder with coil | 3.57 | 37.2 °C | 359 |
| System 628 | Cylinder with coil | 3.51 | 35.4 °C | 348 |
| System 632 | Cylinder with coil | 4.16 | 35.4 °C | 364 |
| System 633 | Cylinder with coil | 3.41 | 38.1 °C | 364 |
| System 634 | Cylinder with plate heat exchanger | 3.51 | 36.6 °C | 364 |
| System 636 | Cylinder with coil | 3.09 | 39.2 °C | 333 |
| System 639 | Cylinder with coil | 3.72 | 35.4 °C | 362 |
| System 643 | Cylinder with coil | 3.98 | 38.7 °C | 359 |
| System 645 | Cylinder with coil | 3.30 | 40.9 °C | 360 |
| System 646 | Cylinder with coil | 4.49 | 32.1 °C | 363 |
| System 649 | Cylinder with coil | 3.96 | 29.2 °C | 355 |
| System 652 | Cylinder with coil | 4.07 | 33.0 °C | 364 |
| System 654 | Cylinder with coil | 4.33 | 35.8 °C | 362 |
| System 655 | Cylinder with coil | 3.74 | 35.9 °C | 364 |
| System 656 | Cylinder with coil | 3.75 | 36.8 °C | 364 |
| System 657 | Cylinder with coil | 3.55 | 33.6 °C | 346 |
| System 661 | Cylinder with coil | 3.89 | 31.5 °C | 353 |
| System 662 | Cylinder with coil | 3.62 | 33.8 °C | 363 |
| System 663 | Cylinder with coil | 3.22 | 37.2 °C | 336 |
| System 666 | Cylinder with coil | 4.22 | 31.7 °C | 364 |
| System 668 | Cylinder with coil | 3.75 | 36.0 °C | 360 |
| System 670 | Cylinder with coil | 4.53 | 34.1 °C | 357 |
| System 671 | Cylinder with coil | 3.76 | 32.7 °C | 364 |
| System 674 | Cylinder with coil | 3.97 | 37.7 °C | 352 |
| System 676 | Cylinder with coil | 3.87 | 36.5 °C | 363 |
| System 685 | Cylinder with coil | 3.70 | 38.4 °C | 364 |
| System 687 | Cylinder with coil | 4.69 | 32.8 °C | 347 |
| System 689 | Cylinder with coil | 3.43 | 33.7 °C | 364 |
| System 690 | Thermal store (heat exchanger on output) | 3.82 | 35.1 °C | 359 |
| System 693 | Cylinder with coil | 3.65 | 36.2 °C | 364 |
| System 696 | Cylinder with coil | 3.80 | 31.9 °C | 363 |
| System 698 | Cylinder with coil | 3.49 | 35.3 °C | 362 |
| System 703 | Cylinder with coil | 4.21 | 38.1 °C | 363 |
| System 704 | Cylinder with coil | 4.61 | 36.0 °C | 332 |
| System 707 | Cylinder with coil | 3.27 | 33.1 °C | 360 |
| System 709 | Cylinder with coil | 4.63 | 30.0 °C | 363 |
| System 710 | Cylinder with coil | 3.91 | 37.2 °C | 364 |
| System 712 | Cylinder with coil | 4.22 | 32.8 °C | 360 |
| System 717 | Cylinder with coil | 3.99 | 32.3 °C | 360 |
| System 719 | Cylinder with coil | 3.97 | 31.5 °C | 362 |
| System 721 | Cylinder with coil | 3.76 | 35.2 °C | 358 |
| System 722 | Cylinder with coil | 3.97 | 34.5 °C | 364 |
| System 723 | Cylinder with coil | 4.20 | 34.6 °C | 363 |
| System 725 | Cylinder with coil | 3.51 | 34.5 °C | 351 |
| System 726 | Cylinder with coil | 3.69 | 33.2 °C | 334 |
| System 730 | Cylinder with coil | 4.52 | 31.1 °C | 364 |
| System 738 | Cylinder with coil | 3.84 | 28.3 °C | 362 |
| System 739 | Cylinder with coil | 3.97 | 32.5 °C | 324 |
| System 740 | Cylinder with coil | 3.83 | 33.5 °C | 363 |
| System 741 | Cylinder with coil | 3.79 | 31.6 °C | 352 |
| System 745 | Cylinder with coil | 3.77 | 30.8 °C | 364 |
| System 747 | Cylinder with coil | 3.52 | 34.3 °C | 363 |
| System 748 | Cylinder with coil | 4.65 | 31.8 °C | 360 |
| System 749 | Cylinder with coil | 4.02 | 34.0 °C | 364 |
| System 752 | Cylinder with coil | 4.29 | 35.3 °C | 355 |
| System 753 | Cylinder with coil | 2.85 | 43.3 °C | 355 |
| System 754 | Cylinder with coil | 4.34 | 32.9 °C | 352 |
| System 755 | Cylinder with coil | 3.93 | 36.8 °C | 364 |
| System 756 | Cylinder with coil | 3.69 | 36.3 °C | 364 |
| System 759 | Cylinder with coil | 4.81 | 32.9 °C | 363 |
| System 761 | Cylinder with coil | 4.19 | 32.5 °C | 363 |
| System 763 | Cylinder with coil | 3.48 | 36.0 °C | 334 |
| System 768 | Cylinder with coil | 3.97 | 32.6 °C | 362 |
| System 769 | Cylinder with coil | 4.49 | 32.4 °C | 364 |
| System 772 | Cylinder with coil | 3.62 | 32.5 °C | 364 |
| System 773 | Cylinder with coil | 4.61 | 31.7 °C | 364 |
| System 775 | Cylinder with coil | 3.18 | 37.8 °C | 319 |
| System 776 | Cylinder with coil | 4.44 | 30.7 °C | 364 |
| System 777 | Cylinder with coil | 5.35 | 26.8 °C | 362 |
| System 778 | Cylinder with coil | 3.32 | 36.9 °C | 362 |
| System 790 | Cylinder with coil | 4.26 | 27.5 °C | 364 |
| System 795 | Cylinder with coil | 3.98 | 34.4 °C | 362 |
| System 800 | Cylinder with coil | 3.85 | 38.8 °C | 364 |
| System 802 | Cylinder with coil | 5.19 | 30.3 °C | 342 |
| System 803 | Cylinder with coil | 3.88 | 35.0 °C | 364 |
| System 804 | Cylinder with coil | 3.75 | 33.0 °C | 349 |
| System 806 | Cylinder with coil | 3.90 | 36.3 °C | 362 |
| System 808 | Cylinder with coil | 2.77 | 36.3 °C | 363 |
| System 809 | Cylinder with coil | 3.56 | 36.8 °C | 363 |
| System 813 | Cylinder with coil | 4.23 | 35.4 °C | 364 |
| System 830 | Cylinder with coil | 3.75 | 39.6 °C | 362 |
| System 834 | Cylinder with coil | 3.78 | 38.7 °C | 363 |
| System 836 | Cylinder with coil | 4.17 | 34.3 °C | 349 |
| System 837 | Cylinder with plate heat exchanger | 4.23 | 35.5 °C | 349 |
| System 839 | Cylinder with coil | 4.10 | 33.2 °C | 354 |
| System 840 | Cylinder with coil | 3.74 | 34.5 °C | 353 |
| System 842 | Cylinder with coil | 4.55 | 31.5 °C | 364 |
| System 844 | Cylinder with coil | 3.57 | 37.0 °C | 361 |
| System 847 | Cylinder with coil | 3.79 | 36.8 °C | 353 |
| System 853 | Cylinder with coil | 3.12 | 37.1 °C | 318 |
| System 858 | Cylinder with coil | 3.48 | 46.0 °C | 364 |
| System 860 | Cylinder with coil | 3.80 | 33.5 °C | 364 |
| System 862 | Cylinder with coil | 4.19 | 34.5 °C | 337 |
| System 863 | Cylinder with coil | 3.86 | 36.0 °C | 356 |
| System 867 | Cylinder with coil | 4.35 | 29.9 °C | 363 |
| System 872 | Cylinder with coil | 4.25 | 34.0 °C | 330 |
| System 873 | Cylinder with coil | 3.93 | 34.9 °C | 337 |
| System 874 | Cylinder with coil | 4.42 | 31.9 °C | 364 |
| System 876 | Cylinder with coil | 4.55 | 27.3 °C | 361 |
| System 877 | Cylinder with coil | 3.94 | 37.1 °C | 348 |
| System 878 | Cylinder with coil | 3.63 | 33.6 °C | 336 |
| System 879 | Cylinder with coil | 4.16 | 33.4 °C | 357 |
| System 881 | Cylinder with coil | 4.09 | 29.4 °C | 364 |
| System 883 | Cylinder with coil | 3.89 | 37.3 °C | 364 |
| System 884 | Cylinder with coil | 3.69 | 35.8 °C | 362 |
| System 885 | Cylinder with coil | 4.55 | 32.4 °C | 339 |
| System 888 | Cylinder with coil | 3.85 | 32.0 °C | 361 |
| System 889 | Cylinder with coil | 4.72 | 29.8 °C | 363 |
| System 891 | Cylinder with coil | 4.48 | 34.6 °C | 352 |
| System 892 | Cylinder with coil | 3.03 | 39.4 °C | 356 |
| System 893 | Cylinder with coil | 4.39 | 34.2 °C | 356 |
| System 894 | Cylinder with coil | 4.23 | 35.3 °C | 314 |
| System 901 | Cylinder with coil | 3.49 | 36.9 °C | 352 |
| System 903 | Cylinder with coil | 3.74 | 35.0 °C | 351 |
| System 906 | Cylinder with coil | 3.14 | 35.8 °C | 344 |
| System 907 | Cylinder with plate heat exchanger | 3.10 | 46.3 °C | 346 |
| System 909 | Cylinder with coil | 3.53 | 36.6 °C | 342 |
| System 910 | Cylinder with coil | 2.92 | 33.5 °C | 356 |
| System 912 | Cylinder with plate heat exchanger | 4.04 | 35.2 °C | 339 |
| System 918 | Cylinder with coil | 4.39 | 31.0 °C | 344 |
| System 922 | Cylinder with coil | 4.58 | 32.4 °C | 331 |
| System 929 | Cylinder with coil | 4.17 | 30.9 °C | 333 |
| System 931 | Cylinder with plate heat exchanger | 2.88 | 34.7 °C | 333 |
| System 940 | Cylinder with coil | 4.69 | 33.1 °C | 307 |
| System 943 | Cylinder with coil | 3.16 | 34.8 °C | 323 |
| System 948 | Cylinder with coil | 4.53 | 32.2 °C | 363 |
| System 959 | Cylinder with plate heat exchanger | 4.26 | 33.6 °C | 301 |
| System 961 | Cylinder with coil | 3.90 | 35.7 °C | 300 |
| System 963 | Cylinder with plate heat exchanger | 3.03 | 40.9 °C | 335 |
| System 977 | Cylinder with coil | 3.91 | 39.2 °C | 342 |
| System 999 | Cylinder with coil | 3.90 | 35.4 °C | 358 |
| System 1008 | Cylinder with coil | 4.99 | 32.4 °C | 322 |
| System 1018 | Cylinder with coil | 2.86 | 37.3 °C | 351 |
| System 1157 | Cylinder with coil | 3.72 | 34.1 °C | 361 |
| System 1197 | Cylinder with plate heat exchanger | 3.00 | 36.7 °C | 359 |
| System 1201 | Cylinder with coil | 4.28 | 31.9 °C | 360 |
| System 1203 | Cylinder with coil | 4.31 | 32.2 °C | 330 |
| System 1235 | Cylinder with coil | 5.27 | 28.1 °C | 363 |
| System 1365 | Cylinder with coil | 4.16 | 35.9 °C | 364 |
| System 1497 | Cylinder with coil | 3.40 | 34.0 °C | 364 |
| System 1537 | Cylinder with coil | 3.77 | 32.8 °C | 361 |
Check installer certification on the MCS Find an Installer page.
If you represent a system owner, or you own a system listed here, and think something is wrong, out of date or missing context, contact us at hello@provenheatpumps.co.uk. We'll review it and, where appropriate, correct the page or publish your response alongside it. System owners can ask for their system to be removed from our pages.