Proven Heat Pumps: all pages

Vaillant Arotherm+ 10 kW: measured performance in monitored homes

Systems recorded on heatpumpmonitor.org as manufacturer "Vaillant", model "Arotherm+", rated output 10 kW: 22 eligible systems. Last checked 14 November 2026.

Median 12-month SCOP4.35range 3.58 to 5.35
Median flow temp while running33.5 °Crange 25.5 to 40.6 °C
Systems22minimum for a model page: 3

The spread between systems mostly reflects differences in homes, design and settings. It is not a measure of the product alone.

Refrigerant as recorded on heatpumpmonitor.org: R290 (22 of 22 systems). The manufacturer lists R290 for the Vaillant Arotherm+ range (Vaillant UK, aroTHERM plus product page).

Systems

SystemLocation (as published)Installer page12-month SCOPDays of dataFlow temp while runningDesign flow temp
System 140BuckinghamshireCustom Renewables4.3136433.3 °C45 °C
System 175WokinghamAlton & Jones Heating Solutions Ltd3.5836240.6 °C40 °C
System 209AberdeenshireAberdeen Air Source Heating Ltd4.1036434.6 °C35 °C
System 258HookUrban Plumbers Ltd4.5036332.7 °C35 °C
System 284WoodleyUrban Plumbers Ltd4.3836333.7 °C40 °C
System 416SurreyClean Heat Solutions Ltd3.9130934.8 °C40 °C
System 479Rowledge Surreyno page5.2336425.5 °C40 °C
System 568Co Antrim - Northern Irelandno page5.0934628.1 °C35 °C
System 630Coventryno page3.5936437.7 °C45 °C
System 643East Yorkshire, UKno page3.9835938.7 °C45 °C
System 687Kington, Herefordshireno page4.6934732.8 °C40 °C
System 752Cardiffno page4.2935535.3 °C45 °C
System 773Cranleigh, SurreyUrban Plumbers Ltd4.6136431.7 °C50 °C
System 777Great Missenden, BuckinghamshireUrban Plumbers Ltd5.3536226.8 °C35 °C
System 802Somerford, CheshireHohm Ltd5.1934230.3 °C35 °C
System 830West YorkshireBritish Gas New Heating Limited3.7536239.6 °C52 °C
System 839Derby, Derbyshireno page4.1035433.2 °C45 °C
System 843Balham, LondonUrban Plumbers Ltd3.6736235.0 °C50 °C
System 891Eastbourne, East SussexOption Energy Solutions Ltd4.4835234.6 °C45 °C
System 893Farnham, SurreyUrban Plumbers Ltd4.3935634.2 °C45 °C
System 957SurreyClean Heat Solutions Ltd4.8136130.7 °C35 °C
System 1203Lancing, West SussexOption Energy Solutions Ltd4.3133032.2 °C38 °C

Definitions. "12-month SCOP" is heatpumpmonitor.org's combined COP (space heating plus hot water) over the last 365 days, from /system/stats/last365 (combined_cop). "Flow temp while running" is the mean flow temperature while the heat pump was running (running_flowT_mean). "Design flow temp" is the value entered for the system. Only UK systems (by published coordinates, with the location text confirming Northern Ireland) with at least 300 days of data in the last 365 days, no heatpumpmonitor.org data flag, and no duplicate key stats are included. Medians and ranges are across the systems listed.

Looking for an installer? Check current MCS certification on the MCS Find an Installer page.

Please read: what this page is and isn't

Right of reply and corrections

If you represent Vaillant or an installer of a listed system, or you own a system listed here, and think something is wrong, out of date or missing context, contact us at hello@provenheatpumps.co.uk. We'll review it and, where appropriate, correct the page or publish your response alongside it. System owners can ask for their system to be removed from our pages.