Proven Heat Pumps: all pages

Vaillant Arotherm+ 12 kW: measured performance in monitored homes

Systems recorded on heatpumpmonitor.org as manufacturer "Vaillant", model "Arotherm+", rated output 12 kW: 18 eligible systems. Last checked 14 November 2026.

Median 12-month SCOP4.27range 3.43 to 4.98
Median flow temp while running33.0 °Crange 28.4 to 36.8 °C
Systems18minimum for a model page: 3

The spread between systems mostly reflects differences in homes, design and settings. It is not a measure of the product alone.

Refrigerant as recorded on heatpumpmonitor.org: R290 (18 of 18 systems). The manufacturer lists R290 for the Vaillant Arotherm+ range (Vaillant UK, aroTHERM plus product page).

Systems

SystemLocation (as published)Installer page12-month SCOPDays of dataFlow temp while runningDesign flow temp
System 196Ashstead, Surreyno page4.3836434.7 °C45 °C
System 208Goudhurst, Kentno page4.0836435.2 °C38 °C
System 277York, North Yorkshireno page4.2530632.2 °C35 °C
System 297Loughboroughno page4.2836332.2 °C46 °C
System 305Drumclog, South Lanarkshireno page4.3633532.2 °C45 °C
System 477Chichester, West SussexRevolution Heating Limited4.9836429.9 °C40 °C
System 574Londonno page4.6136328.4 °C45 °C
System 608WylamGreenhome Heating Limited4.5235731.3 °C45 °C
System 689Havant, HampshireClean Heat Solutions Ltd3.4336433.7 °C48 °C
System 776Thorpe Langton, LeicestershireCustom Renewables4.4436430.7 °C45 °C
System 847Harwell, Oxfordno page3.7935336.8 °C35 °C
System 856Luton, Bedfordshireno page3.5236336.5 °C43 °C
System 873Billericay, EssexLibtek3.9333734.9 °C50 °C
System 885Maidstone, Kentno page4.5533932.4 °C45 °C
System 898Perth, Perthshireno page4.2334234.6 °C40 °C
System 932Birminghamno page4.0136133.8 °C45 °C
System 948Mold, Flintshireno page4.5336332.2 °C45 °C
System 959York, North Yorkshireno page4.2630133.6 °C45 °C

Definitions. "12-month SCOP" is heatpumpmonitor.org's combined COP (space heating plus hot water) over the last 365 days, from /system/stats/last365 (combined_cop). "Flow temp while running" is the mean flow temperature while the heat pump was running (running_flowT_mean). "Design flow temp" is the value entered for the system. Only UK systems (by published coordinates, with the location text confirming Northern Ireland) with at least 300 days of data in the last 365 days, no heatpumpmonitor.org data flag, and no duplicate key stats are included. Medians and ranges are across the systems listed.

Looking for an installer? Check current MCS certification on the MCS Find an Installer page.

Please read: what this page is and isn't

Right of reply and corrections

If you represent Vaillant or an installer of a listed system, or you own a system listed here, and think something is wrong, out of date or missing context, contact us at hello@provenheatpumps.co.uk. We'll review it and, where appropriate, correct the page or publish your response alongside it. System owners can ask for their system to be removed from our pages.